Длительно допустимая температура в процессе эксплуатации 90ºС
Срок службы не менее 45 лет
Структура
- TPJ made of annealed copper wire (single-wire or multi-wire, depending on the diameter of the TPJ)
- Internal insulation made of low-density polyethylene
- External insulation made of high-density polyethylene
Условия эксплуатации и монтажа

The wires are designed for winding the stators of submerged water-filled electric motors that operate for a long time in the water of artesian wells at a voltage of up to 660 V AC with a frequency of 40-60 Hz.

The insulation of the wires is mechanically strong and can withstand at least 100 double drags at a temperature of (25±10) °C.

The insulation is elastic when wound on a rod whose diameter is equal to five times the maximum outer diameter of the wire.

The service life of the wires at an operating temperature of +80 °C is at least 16,000 hours.

The range of temperatures of operation: from -50 °C to +80 °C.

The permissible operating pressure must not exceed 7.09 MPa.

The electrical resistance of the insulation of the wire, measured in water at a temperature of (25±10) °C after being in it for at least 1 hour, recalculated by 1 km of length — not less than 500 Om.

The warranty period of storage is 2 years from the date of manufacture.

Nominal diameter of single-wire and design diameter of multi-wire core, mm

Number of wires Design weight of wire, kg/km Maximum outer diameter of wire, mm Construction length of wire, m
1,4 1 16,2 2,42 95
1,6 1 20,7 2,65 90
1,8 1 26,2 2,95 85
2 1 31,7 3,15 80
2,12 1 36,4 3,5 55
2,36 1 44,3 3,7 70;94
2,5 1 52,2 3,82 70
2,8 1 60,8 4,2 70
3,18 7 64,7 4,7 65
3,54 7 79 5,4 50
3,75 7 88,1 5,4 120
3,96 7 97,6 5,75 110
4,5 7 125 6,25 155
4,8 7 140 6,5 150
5,3 19 167 7,15 140
5,9 19 205 7,8 135
6,25 19 228 8,25 60